Description
Product Overview
Suitable Applications: | exposure to rodent, crush, or cut through force, burial, serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, outdoor such as solar, lighting, etc. |
Construction Details
Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 2 | 22 AWG | 7×30 | TC – Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code | Notes |
---|---|---|---|---|---|
Pair(s) | PE – Polyethylene (Foam) | 0.025 in (0.64 mm) | 0.079 in (2.0 mm) | White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe | HDPE |
Outer Shield
Shield Type | Material | Coverage | Drainwire Type |
---|---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7×30) TC |
Braid | Tinned Copper (TC) | 65% |
Inner Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.053 in (1.3 mm) | 0.350 in (8.89 mm) |
Armor
Armor Type & Material | Armor Thickness | Armor Material Diameter |
---|---|---|
AIA – Aluminum Interlock Armor | 0.025 in (0.64 mm) | 0.560 in (14.2 mm) |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.045 in (1.1 mm) | 0.690 in (17.5 mm) |
Overall Cable Diameter (Nominal): | 0.690 in (17.5 mm) |
Electrical Characteristics
Electricals
Element | Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|---|---|---|---|---|---|
Pair(s) | 18.7 Ohm/1000ft | 11 pF/ft (36 pF/m) | 20.9 pF/ft | 120 Ohm | 78% | 2.7 Amps per Conductor at 25ºC |
Nom. Outer Shield DCR: | 2.95 Ohm/1000ft (9.68 Ohm/km) |
High Frequency (Nominal/Typical)
Element | Frequency [MHz] | Nom. Insertion Loss (Attenuation) |
---|---|---|
Pair(s) | 1 | 0.5 dB/100ft |
Voltage
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
Temperature
UL Temperature | Operating | Installation |
---|---|---|
60°C | -40°C to +60°C | -20°C To +60°C |
Table Notes: | -40C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
8.5 in (220 mm) | 8.5 in (220 mm) |
Max. Pull Tension: | 200 lbs (91 kg) |
Bulk Cable Weight: | 172 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance |
Flammability / Reaction to Fire: | UL 1685 UL Loading, IEEE 1202 |
NEC / UL Compliance: | Article 725, Article 800, CM, PLTC |
CEC / C(UL) Compliance: | CMG, HLBCD |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
History
Update and Revision: | Revision Number: 0.400 Revision Date: 12-22-2023 |
Part Numbers
Variants
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
123107A 0105000 | Black | Reel | 5,000 ft | 612825109631 | C Z |