Description
Product Overview
Suitable Applications: | harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc. |
Construction Details
Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 2 | 18 | 7×26 | TC – Tinned Copper |
Insulation
Material | Color Code |
---|---|
PP – Polypropylene | Blue, Orange and Numbered |
Inner Shield
Shield Type | Material | Coverage |
---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Shield
Shield Type | Material | Coverage |
---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.053 in (1.3 mm) | 0.44 in (11 mm) |
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Inner Shield DCR | Max. Capacitance Unbalance | Nom. Capacitance Cond-to-Shield | Nom. Characteristic Impedence | Nom. Velocity of Prop. | Max. Current |
---|---|---|---|---|---|---|
7.2 Ohm/1000ft | 1.51 Ohm/1000ft (4.95 Ohm/km) | 1.2 pF/ft (3.9 pF/m) | 45 pF/ft | 100 Ohm | 66% | 5.2 Amps per Conductor |
Nom. Outer Shield DCR: | 4.9 Ohm/1000ft (16 Ohm/km) |
High Frequency (Nominal/Typical)
Nom. Insertion Loss (Attenuation) |
---|
0.08 dB/100ft |
High Frequency
Max. Insertion Loss (Attenuation) | Max./Min. Input Impedance (unFitted) [Ohm] |
---|---|
0.091 dB/100ft | 100 |
Voltage
UL Voltage Rating |
---|
300 V RMS |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
105°C | -40°C to +105°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
4.46 in (113 mm) | 4.46 in (113 mm) |
Max. Pull Tension: | 89.6 lbs (40.6 kg) |
Bulk Cable Weight: | 90 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance, Oil Resistance, Burial |
Flammability / Reaction to Fire: | UL1685 FT4 Loading, 1202, IEC 60332-3-24 |
CPR Compliance: | CPR Euroclass: Eca |
NEC / UL Compliance: | Article 725, Article 727, Article 800, CMG, ITC, PLTC |
CEC / C(UL) Compliance: | CMG |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance: | UKCA Mark |
History
Update and Revision: | Revision Number: 0.568 Revision Date: 12-22-2023 |
Part Numbers
Variants
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
1327A 0061000 | Blue, Light | Reel | 1,000 ft | 612825112020 | C |
1327A 0031000 | Orange | Reel | 1,000 ft | 612825112013 | C |