Description
Product Overview
Suitable Applications: | Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas |
Construction Details
RG Type: | Mini 59 |
Conductor
No. of Elements | Size | Stranding | Nom. Diameter | Material |
---|---|---|---|---|
1 | 22 AWG | Solid | 0.65 mm | BC – Bare Copper |
Insulation
Element | Material | Nom. Insulation Diameter |
---|---|---|
Insulated Conductor | PE – Polyethylene (Foam) | 2.9 mm (0.11 in) |
Outer Shield
Layer | Outer Shield Type | Material | Coverage |
---|---|---|---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | 100% |
2 | Braid | Tinned Copper (TC) | 45% |
Outer Jacket
Material | Nom. Diameter |
---|---|
PVC – Polyvinyl Chloride | 4.15 mm |
Table Notes: | According to European Standard EN 50290-2-20 |
Electrical Characteristics
Regularity of Impedance: | Min. 40 dB |
Return Loss (RL)
Frequency | Min. Return Loss |
---|---|
5 – 30 MHz | 20 dB |
30 – 470 MHz | 20 dB |
470 – 862 MHz | 18 dB |
862 – 2400 MHz | 16 dB |
Table Notes: | In each frequency band, 3 peak values up to 4 dB lower are allowed |
Attenuation
Frequency | Nom. Attenuation |
---|---|
5 MHz | 2.7 dB/100m |
50 MHz | 7.5 dB/100m |
100 MHz | 10 dB/100m |
200 MHz | 13.8 dB/100m |
400 MHz | 19.9 dB/100m |
600 MHz | 24.8 dB/100m |
800 MHz | 29 dB/100m |
1000 MHz | 32.5 dB/100m |
1350 MHz | 37.3 dB/100m |
1600 MHz | 40 dB/100m |
1750 MHz | 42.2 dB/100m |
2150 MHz | 47 dB/100m |
2400 MHz | 50.5 dB/100m |
Table Notes: | Max. attenuation 10% higher |
Electricals
Max. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Shield |
Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|---|---|---|---|
55 Ohm/km (17 Ohm/1000ft) | 37 Ohm/km (11 Ohm/1000ft) | 54 pF/m (16 pF/ft) | 75 Ohm | 84% |
Screening
Frequency | Min. Screening Attenuation |
---|---|
100 – 1000 MHz | 80 dB |
Mechanical Characteristics
Temperature
Operating | Installation | Storage |
---|---|---|
-15°C To +70°C | -5°C To +50°C | -15°C To +70°C |
Bend Radius
Stationary Min. |
---|
25 mm (0.98 in) |
Bulk Cable Weight: | 17.8 kg/km |
Standards and Compliance
Environmental Suitability: | Indoor – Euroclass Eca |
Flammability / Reaction to Fire: | IEC 60332-1-2 |
CPR Compliance: | CPR Euroclass: Eca |
ISO/IEC Compliance: | IEC 61196 |
CENELEC Compliance: | EN 50117-1 |
European Directive Compliance: | EU CE Mark |
UK Regulation Compliance: | UKCA Mark |
History
Update and Revision: | Revision Number: 0.205 Revision Date: 12-19-2022 |
Part Numbers
Variants
Item # | Color | Putup Type | Length | EAN |
---|---|---|---|---|
H123A00.00U250 | White | UnReel | 250 m | 8719605085955 |
H123A00.00500 | White | Reel | 500 m | 8719605085924 |